Journal Volumes


Visitors
ALL : 880,334
TODAY : 254
ONLINE : 24



















  JOURNAL DETAIL



Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method


Paper Type 
Contributed Paper
Title 
Determination of Cadmium and Lead in Concrete Roofing Tiles by Differential Pulse Anodic Stripping Voltammetric Method
Author 
Jaroon Junsomboon[a]* and Jaroon Jakmunee[b]
Email 
jaroon@dss.go.th
Abstract:
Differential pulse anodic stripping voltammetric method has been developed for determination of cadmium and lead released from concrete roofing tiles. The sample was extracted with water for 24 h according to the TIS 535-2540 standard method. An aliquot of 5 mL of the extracted solution and 5 mL of 4% v/v acetic acid solution were put in a voltammetric cell. Then, the solution was stirred at 2000 rpm and purged with nitrogen gas for 3 min before the deposition of the metals was carried out by applying a constant potential of -0.90 V versus Ag/AgCl to a hanging mercury drop electrode (HMDE) for 45 s. After that a differential pulse scanning waveform from -0.90 to -0.10 V was applied  and a voltammogram was recorded. Peak current of cadmium and lead were measured at peak potentials of -0.555 and -0.364 V vs Ag/AgCl, respectively. Standard addition procedure was used for quantification. Relative standard deviation for 11 replicate determinations of 8 mgL-1 of both metals were in the range of 1.59 - 1.74%. Percentage recoveries obtained by spiking 8 mgL-1 of cadmium and lead to the sample solution were found to be 107% and with detection limit of 0.15 mgL-1 for both metals. It was found that  contents of cadmium and lead released from the concrete roofing tile samples were in the range of < 0.15 - 0.49 mgL-1 and < 0.15 - 11.95 mgL-1, respectively, which are lower than the regulated values of the Thailand industrial standard (TIS 535-2540). The proposed method is simpler, more convenient and more sensitive than the standard method based on an atomic absorption spectrophototometry.
Start & End Page 
1122 - 1130
Received Date 
2014-03-17
Revised Date 
Accepted Date 
2014-10-27
Full Text 
  Download
Keyword 
differential pulse anodic stripping voltammetry, cadmium, lead, concrete roofing tiles
Volume 
Vol.43 No.5 (OCTOBER 2016)
DOI 
SDGs
View:504 Download:158

Search in this journal


Document Search


Author Search

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

Popular Search






Chiang Mai Journal of Science

Faculty of Science, Chiang Mai University
239 Huaykaew Road, Tumbol Suthep, Amphur Muang, Chiang Mai 50200 THAILAND
Tel: +6653-943-467




Faculty of Science,
Chiang Mai University




EMAIL
cmjs@cmu.ac.th




Copyrights © Since 2021 All Rights Reserved by Chiang Mai Journal of Science