Chiang Mai Journal of Science

Print ISSN: 0125-2526 | eISSN : 2465-3845

1,647
Articles
Q3 0.80
Impact Factor
Q3 1.3
CiteScore
7 days
Avg. First Decision

Effects of Film Thickness and Potential on Response and Interference Suppression of Nitrite Biosensor

Palita Pornchaiwannachat and Saipin Thanachasai
* Author for corresponding; e-mail address: fagispt@ku.ac.th
Volume: Vol.49 No.4 (July 2022)
Research Article
DOI: https://doi.org/10.12982/CMJS.2022.063
Received: 30 November 2021, Revised: 7 March 2022, Accepted: 10 March 2022, Published: -

Citation: Pornchaiwannachat P. and Thanachasai S., Effects of film thickness and potential on response and interference suppression of nitrite biosensor, Chiang Mai Journal of Science, 2022; 49(4): 1076-1087. DOI 10.12982/CMJS.2022.063.

Abstract

     An amperometric myoglobin-based biosensor was developed for detection of nitrite by entrapping myoglobin (Mb) into an electropolymerized polypyrrole (PPy) fi lm deposited on a platinum (Pt) electrode. In order to optimize the sensor response and minimize the interference caused by a common interfering compound, the effects were investigated of the preparation conditions (fi lm thickness corresponding to an electropolymerization charge of 5–400 mC cm-2) and operating conditions (working potentials of +0.60, +0.65 and +0.70 V) on the response and interference suppression of a nitrite biosensor. The current responses to nitrite and ascorbic acid were examined of the obtained PPy/Mb biosensor. The results showed that as the fi lm thickness increased, the response toward nitrite initially decreased and then slightly increased, while the suppression of interference by ascorbic acid increased. The fi lm thickness substantially affected the interference suppression by ascorbic acid because polypyrrole fi lm possesses a size-exclusion property which can suppress electroactive interferent compounds, such as ascorbic acid, and the size exclusion effect relies considerably on the fi lm thickness. An increase in the diffusion barrier against interference with increased fi lm thickness resulted in the enhanced suppression of ascorbic acid. In addition, the results showed that the working potential had a positive infl uence on the response to nitrite across the range studied. However, all the investigated working potentials had a similar effect on the suppression of ascorbic acid.

Keywords: nitrite, myoglobin, biosensor, fi lm thickness, potential

Related Articles

Effects of Sodium Nitrite, Potassium Sorbate and α-Tocopherol on Residual Nitrite, Formations of Biogenic Amines and N-Nitrosamines in Turkish Dry Fermented Sausage (Sucuk)
DOI: 10.12982/CMJS.2024.006.

Bıçakcı Gülsüme and Eren Ömer

Vol.51 No.1 (January 2024)
Research Article View: 1,712 Download: 757
Development and Optimization of an Amperometric Bi-enzyme Biosensor for Aspartame Determination
DOI: 10.12982/CMJS.2023.064.

Tanaporn Tangtawewipat and Saipin Thanachasai

Vol.50 No.6 (November 2023)
Research Article View: 1,352 Download: 585
Outline
Figures