Chiang Mai Journal of Science

Print ISSN: 0125-2526 | eISSN : 2465-3845

1,647
Articles
Q3 0.80
Impact Factor
Q3 1.3
CiteScore
7 days
Avg. First Decision

Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa

Jantima Upan, Suwaphid Themsirimongkon, Surin Saipanya and Jaroon Jakmunee
* Author for corresponding; e-mail address: jakmunee@gmail.com
Volume: Vol.46 No.3 (May 2019)
Research Article
DOI:
Received: 20 September 2018, Revised: -, Accepted: 16 November 2018, Published: -

Citation: Upan J., Themsirimongkon S., Saipanya S. and Jakmunee J., Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa, Chiang Mai Journal of Science, 2019; 46(3): 537-546.

Abstract

Gold nanoparticles (AuNPs) decorated on multi-walled carbon nanotubes (MWCNTs) were used as a modifier on the surface of a screen-printed carbon electrode (SPCE) for sensitive determination of methyldopa, which is widely used as an antihypertensive medicine. The electrochemical oxidation of methyldopa on the modified electrode was carried out in flow injection amperometric (FI–amp) system at the applied potential of +400 mV vs Ag/AgCl. As a result, SPCE modified with 20%w/w of gold nanoparticles on carbon nanotube (AuNPs–CNT/SPCE) provided an excellent sensitivity to methyldopa detection. Morphology of AuNPs–CNT was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy dispersive spectroscopy (EDS), which indicated a proper distribution of AuNPs on CNT and high electrode areas. Several parameters that affect the response of the modified electrode were studied. The plot of peak height versus methyldopa concentration showed a linear range of 0.2–100 µM with a detection limit of 0.1 µM. The proposed flow injection amperometric system was successfully applied for methyldopa determination in real samples.  

Keywords: carbon nanotubes, flow injection analysis, gold nanoparticle, methyldopa, screen printed electrode

Related Articles

Flow Injection System with Amperometric Detection for Determination of Iodine Value of Vegetable Oils
page: 557 - 567

Thidarat Kruatian, Kritsana Jitmanee* and Jaroon Jakmunee

Vol.48 No.2 (March 2021)
Research Article View: 1,071 Download: 577
Flow Injection Potentiometric Method Based on Ce(IV)/Ce(III) Redox Reaction for Determination of Total Antioxidant Capacity
page: 295 - 307

Puttaporn Klayprasert, Kritsana Jitmanee, Napaporn Youngvises and Jaroon Jakmunee*

Vol.46 No.2 (March 2019)
Research Article View: 1,066 Download: 341
Gold-Nanoparticle-Based Fiber Optic Sensor for Sensing the Refractive Index of Environmental Solutions
page: 2168 - 2177

Nongluck Houngkamhang, Sittan Charoensuwan, Onanong Sonthipakdee, Kawin Nawattanapaiboon, Armote Somboonkaew and Ratthasart Amarit

Vol.45 No.5 (Special 2018)
Research Article View: 1,384 Download: 641
Catalytic Oxidation of Glucose with Hydrogen Peroxide and Colloidal Gold as Pseudo-Homogenous Catalyst: A Combined Experimental and Theoretical Investigation
page: 825 - 833

Jitrayut Jitonnom [a] and Christoph Sontag *[a]

Vol.43 No.4 (JULY 2016)
Research Article View: 1,001 Download: 527
Effect of Plasma Power on Copper Substrate Used for Synthesizing Carbon Nanotubes via Alcohol Catalytic Chemical Vapor Deposition (ACVD) Technique
page: 339 - 344

Sureewan Phunwaree*, Wim Nhuapeng, Dheerawan Boonyawan, and Wandee Thamjaree*

Vol.43 No.2 (SPECIAL ISSUE 1)
Research Article View: 1,004 Download: 296
Candle Flame Synthesis and Electrochemical Behavior of Chain-like Carbon Nano-onions on 304 Stainless Steel
page: 745 - 751

Saifon Kruehong, Chaiyaput Kruehong, Prinya Chindaprasirt and Apichart Artnaseaw

Vol.42 No.3 (JULY 2015)
Research Article View: 1,012 Download: 230
Gelatin Microspheres Containing Multi-Walled Carbon Nanotubes: Preparation, Characterization, and Use as a Drug Carrier
page: 1287 - 1300

Saowapa Thumsing [a,b] and Pitt Supaphol [a,b]*

Vol.41 No.5/2 (OCTOBER 2014)
Research Article View: 902 Download: 311
The Underpotential Determination of Lead Using the Laboratory-made Gold Electrode Flow Cell
page: 355 - 369

Prinya Masawat and Saisunee Liawruangrath

Vol.35 No.2 (MAY 2008)
Research Article View: 1,451 Download: 256
Synthesis of Carbon Nanoparticles Using Thermal Co-pyrolysis of Ferrocene and Naphthalene Mixture
page: 379 - 383

Tawatchai Charinpanitkul [a]*, Noriaki Sano [b], P ramote Puengjinda [a] +, P oonlasak Muthak arn [

Vol.32 No.3 (SEPTEMBER 2005)
Research Article View: 1,444 Download: 260
Outline
Figures