Chiang Mai Journal of Science

Print ISSN: 0125-2526 | eISSN : 2465-3845

2,468
Articles
Q3 1.0
Impact Factor
Q2 1.6
CiteScore
7 days
Avg. First Decision

Application of Porous Concrete as a Ventilation Wall for PM2.5 and PM10 Retention

Thanudkij Chareerat, Kanon Niamshiyaphoom, Thada Phongsathid, Naltawat Onputta, Shigemitsu Hatanaka, Dao Janjaroen, Sumrerng Rukzon* and Prinya Chindaprasirt
* Author for corresponding; e-mail address: sumrerng.ruk@rmutr.ac.th
ORCID ID: https://orcid.org/0009-0003-9768-1737
Volume: Vol.53 No.6 (November 2026: In progress)
Research Article
DOI: https://doi.org/10.12982/CMJS.2026.105
Received: 9 April 2026, Revised: 4 August 2026, Accepted: 22 September 2026, Published: -

Citation: Chareerat T., Niamshiyaphoom K., Phongsathid T., Onputta N., Hatanaka S., Janjaroen D., et al., Application of porous concrete as a ventilation wall for pm2.5 and pm10 retention. Chiang Mai Journal of Science, 2026; 53(6): e2026105. DOI 10.12982/CMJS.2026.105.

Graphical Abstract

Graphical Abstract

Abstract

This study investigates the potential use of porous concrete as a passive particulate-retaining ventilation wall material for reducing the penetration of airborne PM2.5 and PM10. The research compares the retention efficiency of porous concrete with that of conventional ventilation concrete blocks through an experimental test chamber in a short-duration laboratory experiment. The study shows that porous concrete exhibits retention efficiencies of 93.5% for PM2.5 and 93.9% for PM10, substantially outperforming traditional blocks, which show only 42.1% and 49.5% for PM2.5 and PM10, respectively. These findings demonstrate the potential of porous concrete as a passive particulate-retaining building component. However, further investigation of long-term particulate loading, airflow resistance, clogging, and regeneration performance is required before practical implementation.

Keywords: porous concrete, particulate matter, sustainable construction, ventilation wall

Related Articles

Effect of Aggregate Size and Void Ratio on Plant Growth in Porous Concrete-Based Hydroponic Systems
DOI: 10.12982/CMJS.2025.073.

Thanudkij Chareerat, Nilobon Nuanlert, Jirawadee Laorchan, Naltawat Onputta,Antika Pranudta, Sumrerng Rukzon and Prinya Chindaprasirt

Vol.52 No.5 (September 2025)
Research Article View: 798 Download: 185
Efficiency of a Tailor Made NO2 Passive Sampler and Correlations of NO2, PM10 and PM10 - bound NO3- in Urban Air of Chiang Mai (Thailand)
page: 386 - 400

Chanakarn Khamkaew [a] and Somporn Chantara*[a,b]

Vol.40 No.3 (JULY 2013)
Research Article View: 1,271 Download: 304
Dispersion of Particulate Matter (PM10) from Forest Fires in Chiang Mai Province, Thailand
page: 39 - 47

Teerachai Amnauylawjarurn, Jiemjai Kreasuwun, Sripen Towta, and Kingkeo Siriwitayakorn

Vol.37 No.1 (JANUARY 2010)
Research Article View: 1,195 Download: 317
Outline
Figures