Chiang Mai Journal of Science

Print ISSN: 0125-2526 | eISSN : 2465-3845

1,647
Articles
Q3 0.80
Impact Factor
Q3 1.3
CiteScore
7 days
Avg. First Decision

Simple Laboratory-made Piezoelectric Sensors for Detection of Selected Gaseous and/or Vapor Sample

Amnat Ruangchaiwat [a], Narabhats Rannurags [a], Sukon Phanichphant [d], Boonsom Liawruangrath [b,c] and Saisunee Liawruangrath*[a,c]
* Author for corresponding; e-mail address: scislwrn@gmail.com
Volume: Vol.43 No.4 (JULY 2016)
Research Article
DOI:
Received: 8 August 2014, Revised: -, Accepted: 24 November 2014, Published: -

Citation: Ruangchaiwat A., Rannurags N., Phanichphant S., Liawruangrath B. and Liawruangrath S., Simple Laboratory-made Piezoelectric Sensors for Detection of Selected Gaseous and/or Vapor Sample, Chiang Mai Journal of Science, 2016; 43(4): 782-792.

Abstract

A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell device constructed in this laboratory afterwards a double-cell device is modified from the prototype device for measuring gaseous / vapour contaminants in air. The PZT detectors were tested for detection of SO2 on the basis of the best known SO2 detection using triethanolamine as coating material. It was found that the dual-cell device was more sensitive to SO2 (48 Hz / ppm) than the single-cell one (6 Hz / ppm). Optimal conditions for the PZT detector were also investigated. The AT-cut quartz crystals with circular shape having thin film gold electrodes on both sides were employed. It was shown that the 10 MHz crytal coated with triethanolamine was more sentitive than the 6 MHz quartz crystal and hence the 10 MHz quartz crystal was selected as optimum. Selectivity of the PZT detector can be achieved by changing the coating materials. Under suitable conditions, choice of appropriate coating materials could be achieved for a number gaseous / vapour samples. The proposed PZT sensors using selective coatings were successfully applied for detection of SO2 and methanol with satisfactory results.  

Keywords: piezoelectric, PZT sensors, methanol, sulphur dioxide

Related Articles

Modern Functional Statistical Analysis: Application to Air Pollutant in London Marylebone Road
DOI: 10.12982/CMJS.2022.029.

Mona Zayed M. Alamer, Omar Fetitah, Ibrahim M. Almanjahie and Mohammed Kadi Attouch

Vol.49 No.2 (March 2022)
Research Article View: 1,649 Download: 432
Real-Time Analysis of Ozone Concentration Using Nonparametric Model of High-Dimensional Data
page: 1173 - 1185

Ibrahim M. Almanjahie, Zoulikha Kaid, Zouaoui Chikr Elmezouar and Ali Laksaci

Vol.48 No.4 (July 2021)
Research Article View: 1,056 Download: 303
Effect of MnO2 Addition on Dielectric, Piezoelectric and Ferroelectric Properties of 0.2Pb(Zn1/3Nb2/3) O3–0.8Pb(Zr1/2Ti1/2)O3 Ceramics
page: 59 - 68

Athipong Ngamjarurojana, and Supon Ananta

Vol.36 No.1 (JANUARY 2009)
Research Article View: 958 Download: 250
Outline
Figures